Operators Manual and Reference Guide
Programming Diagnostic Addresses - A400 and R450 only
For proper operation of all draper table functions, both the “Belt Speed Adjust Option” (Address 066) and “HB
Option” (Address 067) must be enabled , as well as the correct “Platform Type” (Address 071) selected. The
“Deck Shift Option” (Address 068) must also be enabled if you have a Double Swath table.
Only the Platform Type is accessible to the operator. The Options are accessible only to the Dealer.
The dealer should also check with the JD Software Delivery System (SDS) that the installed software version
is current for the windrower.
For Honey Bee Ready windrowers, the HB Option and Belt Speed Adjust Option will already be enabled
and the Platform Type will be preset as a “Honey Bee Draper 21 Foot”. The Deck Shift Option (if
applicable) must be enabled by the dealer.
For non-Honey Bee Ready windrowers, all the Options must be enabled by the dealer and the Platform
Type will be preset as a “Sickle – 14 Foot (if A400) or as a “Rotary Platform - 4 Meter” (if R450) from
factory.
The correct Platform Type must be selected by the operator (or dealer) by changing the value of diagnostic
address 071, using the diagnostics buttons on the cab console and display lines on the PDU.
It is not necessary to start the engine to program diagnostic addresses.
At any time, the back button (E) can be used to go back one step, and
the mode button (A) can be used to exit diagnostics mode.
1. Turn the key to “RUN”
2. To enter diagnostics mode, press Mode button (A)
3. Rotate the dial (B) until “diA” is shown on the display (X). Press the
enter button (C)
4. Rotate the dial (B) until “CAb” is shown on the display (X). Press the
enter button (C)
5. Rotate the dial (B) counter-clockwise until “071” is shown on the
display (X). The display will alternately show “071” and “InP”. The
value of address 071 will be shown on line two of the display (Y),
indicating the platform type (refer to the chart on next page). If the
value shown is not correct, skip to step 6. If the value shown is
correct, no changes are required. Press the mode button (A) to exit
diagnostics mode and turn the key to the “OFF” position.