Page 75
Rev. 02 - 94753
Honey Bee Manufacturing Ltd.
2014 John Deere WS Swather
Operator’s Manual and Reference Guide
NOTE!
JD R450 Install Pump Bracket And Set Pump Flow
Set the pump ow using high idle. Normal pump output is 45 GPM (170 LPM). The output from the
tractor must be set from 29 to 30 GPM (110 – 114 LPM). Install the ow bracket assembly onto the
motor mount, located under the windrower, as shown in Illustration “A”.
1. Remove the two nuts and bolts from the electric
swather pump output controller. Add the bracket as
shown in Illustration “A”, using the new 5/16” x 1”
bolts and nuts provided. Do not tighten yet.
2. Disconnect the linkage lever from the controller by unthreading the Ball & Socket from the
controller. Connect linkage lever by placing the threads of the ball through the hole on the
new bracket, and using the supplied M 6 nut fasten it securely. Use JD supplied ball stud.
3. Tighten the nuts and bolts from step 1 to secure the bracket in place.
4. Install a ow meter inline where the output hose is connected to the table.
5. Start the engine, engage table hydraulics, and set at high idle. Set the draper ow control to
full.
6. Adjust the bracket ne adjustment bolt until the ow meter shows 29 to 30 GPM (110 – 114
LPM). Secure the ne adjustment bolt with locking nut. Re check the ow meter to ensure it
has not changed.
The above procedure sets the correct amount of pump ow for the table. See
“Knife Drive Speed Adjustment” on page 120 for knife speed adjustment
details once the pump ow has been set.
Start at a low ow rate and increase in small increments. Setting ow above the 29
to 30 GPM stated above will result in excessive heating of oil and excessive draper
wear.
WARNING
Illustration B - Page 75
Pump Lever
Old HB
Bracket
Linkage
Illustration A - Page 75 .
To Pump
Lever
5/16” Bolts
JD
Equipment
Linkage
Ball &
Socket
Bracket
Fine Adjustment Bolt
Comments to this Manuals